WALL CONSTRUCTION - OUTER: 95-115 CAVITY: 85-96 INNER: 100-120
LIGHT - MEDIUM DUTY

DOWNLOAD - Click here to download a dwg file of these lintels to use in your CAD drawings.

SC90a
Cavity + Inner Max 205mm
Any variation of design available
Optional Features
Lintray Prefix L
Feature Brick Suffix/FB
Step 20mm Suffix/ST
Flat Base Suffix/F
Cant Outer 50mm Suffix/C
Wide Outer 125mm Suffix/WO
Lintels Properties
Ixx cm4 145.67
Zxx cm3 20.32
Weight kg/m 11.28
Area cm2 14.36
Ryy cm 6.61

Opening
Size
Lintel
Lengh
Safe UDL kN Load Ratio 1:5
600 900 20
750 1050 20
900 1200 20
1050 1350 20
1200 1500 18
1350 1650 16
1500 1800 15
1650 1950 13
1800 2100 -
1950 2250 -
2100 2400 -
2250 2550 -
2400 2700 -
2550 2850 -
2700 3000 -
2850 3150 -
3000 3300 -
3150 3450 -
3300 3600 -
3450 3750 -
3600 3900 -
3750 4050 -
3900 4200 -
4050 4350 -
4200 4500 -
4350 4650 -
4500 4800 -
 
SC90b
Cavity + Inner Max 205mm
Any variation of design available
Optional Features
Lintray Prefix L
Feature Brick Suffix/FB
Step 20mm Suffix/ST
Flat Base Suffix/F
Cant Outer 50mm Suffix/C
Wide Outer 125mm Suffix/WO
Lintels Properties
Ixx cm4 374.64
Zxx cm3 37.76
Weight kg/m 13.46
Area cm2 17.14
Ryy cm 6.13

Opening
Size
Lintel
Lengh
Safe UDL kN Load Ratio 1:5
600 900 30
750 1050 30
900 1200 30
1050 1350 30
1200 1500 30
1350 1650 30
1500 1800 28
1650 1950 25
1800 2100 23
1950 2250 22
2100 2400 20
2250 2550 19
2400 2700 18
2550 2850 17
2700 3000 16
2850 3150 -
3000 3300 -
3150 3450 -
3300 3600 -
3450 3750 -
3600 3900 -
3750 4050 -
3900 4200 -
4050 4350 -
4200 4500 -
4350 4650 -
4500 4800 -
 
SC90c
Cavity + Inner Max 205mm
Any variation of design available
Optional Features
Lintray Prefix L
Feature Brick Suffix/FB
Step 20mm Suffix/ST
Flat Base Suffix/F
Cant Outer 50mm Suffix/C
Wide Outer 125mm Suffix/WO
Lintels Properties
Ixx cm4 1051.27
Zxx cm3 75.71
Weight kg/m 17.06
Area cm2 21.72
Ryy cm 5.56

Opening
Size
Lintel
Lengh
Safe UDL kN Load Ratio 1:5
600 900 50
750 1050 50
900 1200 50
1050 1350 50
1200 1500 50
1350 1650 50
1500 1800 50
1650 1950 50
1800 2100 47
1950 2250 44
2100 2400 41
2250 2550 39
2400 2700 36
2550 2850 34
2700 3000 33
2850 3150 31
3000 3300 30
3150 3450 28
3300 3600 27
3450 3750 26
3600 3900 25
3750 4050 24
3900 4200 23
4050 4350 22
4200 4500 21
4350 4650 21
4500 4800 20
 
MC90a
Cavity + Inner Max 205mm
Any variation of design available
Optional Features
Lintray Prefix L
Feature Brick Suffix/FB
Step 20mm Suffix/ST
Flat Base Suffix/F
Cant Outer 50mm Suffix/C
Wide Outer 125mm Suffix/WO
Lintels Properties
Ixx cm4 822.92
Zxx cm3 86.91
Weight kg/m 16.84
Area cm2 21.43
Ryy cm 5.84

Opening
Size
Lintel
Lengh
Safe UDL kN Load Ratio 1:19
600 900 40
750 1050 40
900 1200 40
1050 1350 40
1200 1500 40
1350 1650 40
1500 1800 40
1650 1950 40
1800 2100 40
1950 2250 40
2100 2400 40
2250 2550 40
2400 2700 40
2550 2850 40
2700 3000 38
2850 3150 36
3000 3300 34
3150 3450 32
3300 3600 29
3450 3750 27
3600 3900 25
3750 4050 23
3900 4200 21
4050 4350 20
4200 4500 18
4350 4650 17
4500 4800 16