BRICK SUPPORT ANGLE

DOWNLOAD - Click here to download a dwg file of these lintels to use in your CAD drawings

LA 160
Optional Features
Top bend omitted, M13 holes added at 450mm ctrsSuffix/H
Plaster Key Base Suffix/PB
Cant Outer 50mm Suffix/C
Wide Outer 125mm Suffix/WO
Lintels Properties
Ixx cm4 263.13
Zxx cm3 24.40
Weight kg/m 6.22
Area cm2 7.92
Ryy cm 2.64

Opening
Size
Lintel
Lengh
Safe UDL
kN
600 900 13
750 1050 13
900 1200 13
1050 1350 13
1200 1500 13
1350 1650 10
1500 1800 9
1650 1950 8
1800 2100 8
1950 2250 7
2100 2400 -
2250 2550 -
2400 2700 -
2550 2850 -
2700 3000 -
2850 3150 -
     
Safe UDL with bolted angle (option H) 20 kN/metre Safe load using Hilti M12, HAS 66342 (or similar), 30N concrete.
LA 215
Optional Features
Top bend omitted, M13 holes added at 450mm ctrsSuffix/H
Plaster Key Base Suffix/PB
Cant Outer 50mm Suffix/C
Wide Outer 125mm Suffix/WO
Lintels Properties
Ixx cm4 661.17
Zxx cm3 51.91
Weight kg/m 11.67
Area cm2 14.85
Ryy cm 1.85

Opening
Size
Lintel
Lengh
Safe UDL
kN
600 900 20
750 1050 20
900 1200 20
1050 1350 20
1200 1500 20
1350 1650 20
1500 1800 15
1650 1950 15
1800 2100 15
1950 2250 10
2100 2400 10
2250 2550 10
2400 2700 10
2550 2850 -
2700 3000 -
2850 3150 -
     
Safe UDL with bolted angle (option H) 20 kN/metre Safe load using Hilti M12, HAS 66342 (or similar), 30N concrete.
LA 160/6
Optional Features
Top bend omitted, M13 holes added at 450mm ctrsSuffix/H
Plaster Key Base Suffix/PB
Cant Outer 50mm Suffix/C
Wide Outer 125mm Suffix/WO
Lintels Properties
Ixx cm4 502.33
Zxx cm3 46.57
Weight kg/m 12.30
Area cm2 15.66
Ryy cm 2.68

Opening
Size
Lintel
Lengh
Safe UDL
kN
600 900 25
750 1050 25
900 1200 25
1050 1350 25
1200 1500 25
1350 1650 25
1500 1800 20
1650 1950 20
1800 2100 20
1950 2250 15
2100 2400 15
2250 2550 15
2400 2700 15
2550 2850 10
2700 3000 10
2850 3150 10
     
Safe UDL with bolted angle (option H) 30 kN/metre Safe load using Hilti M12, HAS 66342 (or similar), 30N concrete.
LA 215/6
Optional Features
Top bend omitted, M13 holes added at 450mm ctrsSuffix/H
Plaster Key Base Suffix/PB
Cant Outer 50mm Suffix/C
Wide Outer 125mm Suffix/WO
Lintels Properties
Ixx cm4 957.24
Zxx cm3 68.55
Weight kg/m 14.85
Area cm2 18.90
Ryy cm 2.90

Opening
Size
Lintel
Lengh
Safe UDL
kN
600 900 40
750 1050 40
900 1200 40
1050 1350 40
1200 1500 40
1350 1650 40
1500 1800 35
1650 1950 35
1800 2100 35
1950 2250 30
2100 2400 30
2250 2550 25
2400 2700 25
2550 2850 20
2700 3000 20
2850 3150 20
     
Safe UDL with bolted angle (option H) 30 kN/metre Safe load using Hilti M12, HAS 66342 (or similar), 30N concrete.